PWW-800GF3-8M33-WPG1100
  • PWW-800GF3-8M33-WPG1100
  • PWW-800GF3-8M33-WPG1100
  • PWW-800GF3-8M33-WPG1100
  • PWW-800GF3-8M33-WPG1100
  • PWW-800GF3-8M33-WPG1100
  • PWW-800GF3-8M33-WPG1100
  • PWW-800GF3-8M33-WPG1100
  • PWW-800GF3-8M33-WPG1100
  • PWW-800GF3-8M33-WPG1100
  • PWW-800GF3-8M33-WPG1100
  • Product Parameters

Gen-set specifications

ModelWPG1000*73
Standby Rating kVA/kWe1000/800
Prime Rating kVA/kWe/
Voltage V400/230
Frequency Hz50
Power Factor0.8(lagging)
No. of Phases3
Fuel consumption@25%/ 50% / 75%(L/h)41.5 / 83.0 / 124.5
Fuel consumption@100% / 110%(L/h)166.0/ 182.6
Sound@1m(dB (A))Open≤103 ; Silence ≤95
Ambient temp (℃)-10~45
Gen-set regulation classISO 8528-5 G2
Steady-state voltage deviation≤±2.5%
Transient voltage deviation (100%sudden power decrease/increase)≤+25% ;≤-20%
Steady-state frequency band≤1.5%
Transient frequency deviation from rated frequency (100%sudden power decrease/increase)≤+12% ;≤-10%

WEICHAI GEN-SETS DATASHEET

Genset appearance

Standard Features

  • ECU
  • DC24 Electric starter
  • WHC9320CAN
  • Closed water-cooled
  • IP23
  • H type insulation
  • Air filter
  • Muffler
  • Circuit Breaker
  • Starting batteries
  • with connective wires
  • Radiator
  • Oil Drain Valve
  • Forklift Groove
  • Shock Absorber
  • Color: Weichai blue (B,F)/beige canopy and black chassis (L) / white (C)
  • Packaging: Wound film packing
  • PMG

Options

  • Line Voltage 380V/415V
  • Line Voltage 440V/480V
  • Voltage 6.3kV/10.5kV /13.8kV
  • Single Voltage 220V/230V
  • Automatic Transfer Switch
  • Automatic Parallel system
  • Engine Heater (water)
  • Engine Heater (air inlet)
  • Alternator heater
  • External fuel tank (1000L/1500L)
  • AREP

Engine

  • Weichai 8M33 series, 8 cylinder, V-type, 4 stroke, radiator cooled engine
  • Well-designed air handling system with
  • Dry type, Replaceable paper element air cleaner with restriction indicator
  • Air to air after cooling
  • Optimized turbocharger for increased altitude capabilities
  • High efficiency, large heat area intercooler, reduce the air temperature after the intercooler
  • High pressure common rail fuel system
  • Radiator
  • Electrical starter motor with soft start engagement feature
  • Intelligent fuel injection technology to start fast guarantee
  • Battery charging alternator
  • 2 x 12 V DC batteries
PWW-800GF3-8M33-WPG1100

Engine specifications

MakeWEICHAI
Mode8M33D895E310
Rated Speed r/min1500
Prime Power kW815
Overload Power kW895
CoolingLiquid cooled
GovernorECU
AspirationSupercharged intercooling
No. of cylinders8 , V-type
Bore (mm) x Stroke (mm)150×185
Displacement (L)26.1
Starting system24VDC
Total coolant capacity (L)152
Total lubrication system capacity (L)105
Cooling fan airflow(m³/min)1430
Exhaust Temperature (°C)≤780
Recommended air flow @ PRP (m³/min)46.6
Exhaust back pressure (mBar)≤75
Radiator design temperature (℃)45

Control Module Specifications

The WHC9320CAN is an Auto Mains Failure Control Module

  • Back-lit LCD display
  • 3 Phase generator and 3 Phase Mains monitoring
  • Monitoring speed, frequency, voltage, current, oil pressure, coolant temperature and fuel level
  • Display warning, shutdown and engine status information
  • Hours counter provides accurate information for monitoring and maintenance
PWW-800GF3-8M33-WPG1100

Alternator

  • Brushless type, Screen protected, Revolving field, Self excited alternator conforming to IEC 60034-1
  • Best in class efficiency
  • Steel casing
  • Compact design with sealed bearings for longer life and lesser maintenance
  • IP23 standard protection level
  • Impregnation on all wound components for better mechanical strength
PWW-800GF3-8M33-WPG1100

Alternator specifications

MakeWEICHAI
Alternator FrameWHA-1000-4/0.4
Exciter TypeSelf-excitation
EnclosureIP23
Voltage regulation≤±1%
Class of InsulationH
Winding Pitch2/3
RotorSingle bearing

Remarks

Prime power(PRP)

Prime power is defined as being the maximum power which a generating set is capable of delivering continuously while supplying a available electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufactures.

The permissible average power output, over 24h of operation shall not exceed 70% of the PRP unless otherwise agreed by the RIC engine manufacturer.

Emergency standby power(ESP)

Emergency standby power is defined as the maximum power available during a available electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200h of operation per year with the with the maintenance intervals and procedures being carried out as prescribed by the manufactures.

The permissible average power output, over 24h of operation shall not exceed 70% of the ESP unless otherwise agreed by the RIC engine manufacturer.

Standard Conditions

Standard operating environment: ambient temperature is 5℃~40℃, the altitude is less than 1000m,the relative humidity is less than 90%(25℃), and there is no dust, sand dust, salt fog, mold, condensation environment, etc. If the operating environment exceeds the above requirements, please contact the factory and consult.

Ambient adaptability protection measures for alternators

Ambient typeAmbient descriptionMeasures of protection
General AmbientThe air is clean and dry, the humidity is ≤90%, and the distance from the coastline is ≥ 30km; Non-industrial ambient (chemical splash, acid-base steam, corrosive environment, etc.)standard configuration
Humid AmbientThe humidity above 90% or condensation occursAnti-condensation heating
Saltspray AmbientSalt fog crystals are produced in seaside (< 30km from the coastline) or island AmbientAnti-condensation heating;Spray three-proof paint on winding surface;Spraying epoxy protection for parts and structures.
Dust AmbientThe ambient where mining, building construction, desert Gobi or sandstorm occurImprove the protection level of the alternator to IP44;Install filters.

If you need to use protective measures beyond the standard, please contact the factory and consult.

Special working condition

If the operating conditions of the generator meet the following conditions, please contact the factory and consult.

  • Multistage parallel operation
  • Grid-connected operation
  • As the main power supply, it runs continuously for a long time
  • The load includes a high power motor type load
  • Capacitive load
  • Special ambient such as high temperature, cold and plateau

Typical Enclosed Genset Dimensions

Genset ModelLength A(mm)Width B(mm)Height C(mm)Wet Weight*(kg)Standard Fuel tank Capacity (L)
WPG1000/B734030187121316900/

*: Include coolant and oil.

Genset Drawings

PWW-800GF3-8M33-WPG1100
Open Genset

Availability Details

  • Air intake system: Air filter;
  • Cooling system: Closed-loop cooling radiator;
  • Fume extraction system: Expansion pipe, muffler and mating flange;
  • Fuel system: Inlet return port connector, fuel filter;
  • Lubrication system: Oil pan, oil filter;
  • Vibration damping system: Rubber shock absorber;
  • Electrical system: Control screen and switch cabinet:
  • Silent System: Silencing box/container (silent unit configuration)

Note 1: Silent generator sets (L Series, C Series) can be used directly after installation on the ground, without the need for separate installation accessories, and open generator sets require appropriate installation accessories to install fume extraction systems, etc.

Note 2: The factory does not provide on-site installation accessories such as exhaust straight pipe, elbow, radiator shroud, etc. to the unit itself. The buyer needs to consider the installation of the accessories and the installation project in advance;

8 / 14

Related Products

Contact Us

Contact Us

+86 189-5531-5152

Email:[email protected]

Work:Monday to Friday,9:30-18:30

WhatsApp
SHARE
TOP